Diabetes Glucose Meter Indications for Use
The Sindhm Diabetes Glucose Meter blood glucose monitoring system is intended for use outside the body (in vitro diagnostic use only). It should be used only for testing blood glucose(sugar) with venous blood, capillary whole blood (fingertip) samples. Blood glucose testing of venous blood can only be done/operated by a professional. The product itself cannot be directly used for diagnosing diabetes and must be professionally diagnosed and prescribed by the physician.
The Sindhm Diabetes Glucose Meter blood glucose monitoring system uses the latest technology to provide users with easy and comfortable testing. The system requires only a 1.2 μl of the blood sample to complete the testing in only 5 seconds.
The selling point of the Diabetes Glucose Meter blood glucose monitoring system:
â‘ Requires no codingï¼›allowing you to save time and avoid human error due to coding.
â‘¡ Has memory and data management capabilities. It gives users powerful graphic tools to manage diabetes.
Product Parameter
Product name |
Diabetes glucose meter for blood glucose solution |
Carton Size |
55*34*30cm |
Color Box Size |
220*195*60mm |
Weight per Kit |
0.515kg/pcs,20PCS/carton |
Function |
Test fingertip whole blood and venous whole blood glucose |
Application |
Home self-test |
Blood Sample |
fresh capillary whole blood |
Calibration sample |
venous plasma |
Test Range |
20-600 mg/dL (1.1-33.3 mmol/L) |
Test Time |
5s |
Tiny Blood Volume: |
1.2μl |
HCT |
0-70% |
Warranty |
10 years |
Memory |
450 test memories, it can save pre & post-meal glucose level tests of 7/14/21/28 days averages. |
Battery type |
CR2032 |
Package type |
1 kit: 1 glucose meter + 1 lancet device + 50 test strips +50 lancets+ manual+ bag |
Health Information
Hematocrit, also known as Hct, refers to the proportion of anticoagulated whole blood precipitated blood cells (mainly red blood cells) in whole blood after centrifugation. This value varies with age and gender. Under normal circumstances, hematocrit (adult): male: 40-50%, female: 35 -45%.
Diabetics are prone to serious complications due to poor blood glucose control, such as high blood pressure, cardiovascular disease, renal failure, retinopathy, etc. Therefore, the blood glucose meter is a very important blood glucose monitoring system for diabetic patients.
According to the recommendations of the American Diabetes Association, diabetics and nondiabetics should try to keep their blood glucose within the standard blood glucose range, as shown in the following table:
Plasma Glucose Range |
Time |
Non-Diabetic |
Diabetic |
mg/dL |
mmol/L |
mg/dL |
mmol/L |
Fasting or Pre-meal |
<100 |
<5.5 |
80-130 |
4.4-7.2 |
Two hours after meals |
<140 |
<7.8 |
<180 |
<10 |
REF. American Diabetes Association: Diabetes Care, Volume 42, Supplement 1, January 2019, S4-S80.
The above range is for reference only, please consult medical staff about the range of blood glucose that suits you.
http://www.sdglucometers.com/